Outdated Drivers
Can cause hardware related Errors. Check your PC Drivers now.






This table represents the errors reported by Patton Remote Access servers. All access server references contained herein are Copyright© Patton RAS, used here for educational purposes, and with permission of Patton RAS.


Error # Fix / Info Termination Code Termination Reason
0 none stillActive(0) Call is currently connected
1 none notKnown(1) Unknown
2 none idleTimeout(2) Call exceeded idle timeout parameter
3 none killed(3) Call terminated by administrator
4 none takeLinkDown(4) Unknown
5 none userHangup(5) DSP discovered remote modem was hung up abruptly. Examples could be that the phone line was pulled out of the wall jack or the user terminated the communications without closing the connection down. If the modems are unable to bring up the physical line by successfully negotiating the modulation, userHangup will be registered if the remote modem gave up trying to complete the call.
6 none modemCanNotConnect(6) The modems are not able to bring up the physical line by successfully negotiating the modulation. The RAS has given up trying further to complete the physical connection
7 none modemError(7) Unknown
8 none pppClose(8) This termination reason will be given after PPP is initated and the connection is disconnected. An example would be if LCP negotiations failed. Another cause could be if the bundlehead in a multilink call is terminated before the tunneled call is termination.
9 none lcpClose(9) Close initiated by LCP. This is a normal shutdown of a call
10 none loginTimeOut(10) Exceeded login timeout parameter
11 none userTerminated(11) A problem is discovered initiating the dial-in users telnet, rlogin or tcpclear session.
12 none noPoll(12) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
13 none ipcPutMsdErr(13) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
14 none invalidAuthMsg(14) Unknown
15 none pollErr(15) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
16 none ioctlErr(16) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
17 none pppPutMsgErr(17) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
18 none dspIoctlErr(18) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
19 none timerErr(19) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
20 none authClean(20) Unknown
21 none maxNumCalls(21) Exceeds maximum number of channels that can be allocated to the same call.
22 none pppOpenErr(22) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
23 none ipLinkErr(23) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
24 none notPapReq(24) The RAS is waiting for a PAP request packet containing the username/password for a call but the packet received was not a PAP request packet.
25 none pppLinkErr(25) Unknown
26 none tcpOpenErr(26) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
27 none tcpPushErr(27) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
28 none tcpPutMsgErr(28) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
29 none invalidPrim(29) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
30 none noIpPoolAddr(30) Authentication server did not assign an IP address and access had no IP address pool defined to assign an IP address
31 none noIpAddr(31) Authenticator did not return an IP address for the service (eg telnet or rlogin) and the default service defined does not specify the service IP address
32 none maxLoginAttempts(32) Exceeded maximum login attempts as defined under the Dial-in link
33 none noTimers(33) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
34 none tcpLinkErr(34) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
35 none dspLinkErr(35) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
36 none dspPutMsgErr(36) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
37 none noDsp(37) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
38 none lisIpcErr(38) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
39 none dspOpenErr(39) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
40 none invalidCode(40) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
41 none callContention(41) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
42 none dspCommErr(42) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
43 none unknownBearerContent(43) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
44 none invalidDefaults(44) Default service is set to a value other than rlogin, telnet, tcpraw, ppp, slip or vpn when using a login technique of None. No IP address is defined when using rlogin or telnet. Invalid telnet or rlogin services ports have been defined in the default service.
45 none noDspAvailable(45) When the RAS attempted to connect the incoming call to an available DSP, no DSP could be found.
46 none dspOutOfState(46) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
47 none dspRequestUnsupported(47) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
48 none dspBadPrimitive(48) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
49 none papAuthenticationFailure(49) Invalid username/password combination
50 none papInvalidPacket(50) Non-printable characters in username or password received from remote end during authentication
51 none authenServerTimeout(51) Authentication request timed out. The RADIUS server did not send a response to the authentication request before the timer expired.
52 none authenAccountingTimeout(52) Accounting request timed out. The RADIUS server did not send a response to the accounting request before the timer expired.
53 none unknownProtocol(53) The user imitates a PPP connection but the RADIUS replies to the RAS that the user is not allowed to connect using PPP.
54 none mfr2DisWaitCalled(54) Call disconnected while we were waiting for the next expected called number digit. The number of called number digits expected is more than the digits actually being sent or the Last response code is configured incorrectly so the RAS and switch can not continue on with the interregister signaling.
55 none mfr2DisAckCalled(55) Call disconnected while we were in the process of sending back the ack tone for a called number digit or while we were waiting for the termination of the far end tone in response to our ack.
56 none mfr2DisAckLastCalled(56) Call disconnected while we were in the process of sending back the ack tone for the last expected called digit or while we were waiting for the termination of the far end tone in response to our ack.
57 none mfr2DisWaitCalling(57) Call disconnected while we were waiting for the next expected calling number digit. The number of calling number digits expected is more than the digits actually being sent or the Last response code is configured incorrectly so the RAS and switch can not continue on with the interregister signaling.
58 none mfr2DisAckCalling(58) Call disconnected while we were in the process of sending back the ack tone for a calling number digit or while we were waiting for the termination of the far end tone in response to our ack
59 none mfr2DisAckLastCalling(59) Call disconnected while we were in the process of sending back the ack tone for the last expected calling digit or while we were waiting for the termination of the far end tone in response to our ack.
60 none mfr2DisWhileComplete(60) Call disconnected after the last expected digit was sent and acked. The number of calling digits expected may be less than the number of digits sent or the last response code for the calling number is incorrect.
61 none tcpSideClosure(61) There is a problem connecting to the IP Address or the port specified.
62 none telnetError(62) There is a problem connecting to the IP Address or the port specified.
63 none rloginError(63) There is a problem connecting to the IP Address or the port specified.
64 none exceedsMultiLinkLimit(64) Exceeds multilink channel limit set either on the remote access server or in the user entry on the RADIUS server
65 none lcpNegotiationFailure(65) Unknown
66 none sessionTimeout(66) The length of the connection exceeds the session time limit allowed
67 none tcpConnAborted(67) Connection to the remote service has been disconnected abruptly. For example, the administrator of the remote machine killed the process.
68 none tcpNoBuffers(68) Internal RAS error. Please contact Patton technical support if you see these termination reason:
69 none tcpConnRefused(69) Connection to specified service on the remote machine was refused
70 none tcpConnReset(70) Connection was reset
71 none tcpTimedOut(71) Request to initiate connection to the remote service timed out. Connection timed out because the remote side did not respond on the connection in a timely manner.
72 none noLnsIpAddr(72) Unknown
73 none noDefaultLns(73) Unknown
74 none vpnPeerRejected(74) Unknown
75 none udpOpenError(75) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
76 none udpBindErr(76) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
77 none lstpOpenErr(77) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
78 none l2tpLinkErr(78) Internal RAS error. Please contact Patton technical support if you see these termination reasons.
79 none reLinkErr(79) Internal RAS error. Please contact Patton technical support if you see these termination reasons.





This page was last modified on Saturday, 05-Feb-2011 15:10:28 EST.




 
This website is ©1999-Present Bradford Liedel DBA ModemHelp Networks and Web Services. Mason, MI 48854 USA. All rights reserved.